Meziere Enterprises

Meziere LS Extreme Heavy Duty Electric Water Pump 300 Series - WP333

In stock - 5-10 days to dispatch from warehouse SKU: MZ-WP333S
$1,815.00

Availability: 5-10 days from warehouse

Check fitment and quantity before ordering.

Need help? Contact CJs to confirm fitment.
Found a better price? We'll beat it Submit the advertised price and product URL for review.

Price must be currently advertised and publicly available. CJs may request extra details before approving a match.

Specifications

Manufacturer torque spec
15 ft/lb
Compatible engines
LS Series
Product details

We bring you the solution for LS-based, extreme-duty engine cooling. The 55 GPM pump is a great solution for high-compression, high-horsepower applications where superchargers, turbos, or nitrous systems are employed. These pumps are the highest flowing electric pumps available and come with a two year warranty.

Included fittings: 1.75 in. inlet fitting and 1.5 in. outlet fitting.

Installation instructions WP333 GM LS-x 55 GPM Centrifugal 12V Electric Water Pump

Important: AN fittings are available for this pump.

In the box

Qty Item
1 Electric Pump WP333
1 1.75 in. lower hose fitting
1 1.5 in. upper hose fitting
6 8mm x 1.25P x 90mm SSSHCS bolts and washers
2 GM water pump gaskets, P/N 12630223
1 Wiring harness with 20 amp fuse
2 Contingency decals

Tools needed

  • Scraper or wire brush
  • Brake cleaner
  • Gasket sealant: Form-a-Gasket Aviation, Form-A-Gasket 2 Non-Hardening, Gaskacinch, or RTV silicone
  • Thread sealant: RTV silicone or liquid pipe thread sealant
  • 6mm hex socket

Mounting

Remove the stock water pump. Clean and degrease the gasket area, then coat both sides of the gasket with the recommended sealant. Tack the gaskets to the back of the Meziere pump and align them with the bolt holes. Apply a small amount of sealant to the supplied hardware threads to help prevent leaks, then bolt the pump in place.

Torque note: Run all six bolts up snug before tightening to the recommended 15 ft-lb.

Inlet and outlet fittings

The inlet and outlet fittings come installed. They have an o-ring seal. If you remove them, use some grease on the o-ring when reinstalling.

Thermostat and heater lines

The pump has a provision under the upper hose fitting for a thermostat. An early Chevy V8 thermostat is required; Stant number 13006 for 160 degrees F is one example.

The pump also has two -08AN ORB ports that can be used for heater hose connections. Meziere part number WPM58 or WPM34 can be used in most applications that use stock hoses.

Wiring the pump

Wire Connection
Blue 12 volt positive switched source
Black Ground

Supply and ground wires should be 14 gauge minimum. All switches should be rated at 20 amps or better.

Warranty warning: Not using a protection circuit, such as the supplied fused circuit, will void your warranty.

Startup and running

Fill the cooling system. Replace the fill cap and turn on the pump. Remove the fill cap and top off the coolant level. Recheck the level after one heat cycle.

Do not run the pump dry for more than a few seconds.

Finish care

Your pump comes polished and waxed. Occasional waxing will allow dirt or debris to be wiped right off and can offer some UV protection. Anodized colour can fade from prolonged exposure to sunlight.

Installation information sourced from Meziere Enterprises documentation.

Fitment

Confirm fitment before ordering. Contact us if you need help matching parts to your build.

Frequently Bought Together